Click Here to see more reviews about: Honeywell S8610U1003 gas universal intermittent pilot control module - REPLACED BY S8610U3009
Intermittent Pilot Module, Control Module for Natural/LP Gas System S8610U Universal Intermittent Pilot Module APPLICATION The S8610U Universal Replacement Ignition Module is designed to provide easy field replacement of a wide range of intermittent pilot ignition modules manufactured by Honeywell, Robertshaw, Johnson and others. The S8610U Module provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot central furnaces, residential boilers, and other heating appliances. FEATURES Provides up to 1.0A pilot and 2.0A main valve current rating. System uses rectification principle for flame sensing. For use with separate igniter and sensor or combination igniter-sensor. Q345, Q348, Q362, Q373 or Q381 Igniter-sensor recommended as combination igniter-sensor; Q179C with igniter and sensor mounted on one bracket, or Q354 Sensor with Q345, Q348, Q362, Q373 or Q381 Igniter-sensor recommended as separate igniter and sensor. Q3450/Q3480 Hot Surface Pilot hardware plugs directly into system control. Can be used on natural or LP gas; provides 100 percent shutoff on ignition failure. Waits six minutes nominal following shutoff, then reinitiates the pilot ignition sequence. The ignition trial-shutoff-wait cycle repeats until the pilot lights or the call for heat ends. Replaces numerous Honeywell and competitor modules. Capacitive discharge spark output. Temperature rating is -40F to 175F (-40C to 79C)when used with 1.0A